CVE-2026-19738
MEDIUMDescription
The Bluetooth Link Layer Control Procedure (LLCP) implementation for Connected Isochronous Stream (CIS) creation retains an RX node (ctx->node_ref.rx, marked NODE_RX_TYPE_RETAIN) so it can later be reused as the host notification — on the peripheral while awaiting the Host's reply to an LL_CIS_REQ, and on the central for the whole duration of a locally initiated CIS Create. In subsys/bluetooth/controller/ll_sw/ull_llcp_cc.c, the "invalid PDU received" paths of llcp_rp_cc_rx() and llcp_lp_cc_rx() terminated the connection and completed the procedure without releasing that retained node, breaking the invariant checked in llcp_lr_check_done() and llcp_rr_check_done() and orphaning the node's memory. A peer device within radio range can reach this with a single extra LL Control PDU on an unauthenticated, unencrypted ACL link. Against a peripheral, the attacker sends a valid LL_CIS_REQ and then, before the Host replies, any unrelated LL Control PDU (for example LL_VERSION_IND), which ull_cp_rx() routes into the active remote procedure. Against a central performing a CIS Create, a malicious peripheral answers with LL_UNKNOWN_RSP for CIS_REQ, which is dispatched into the active local procedure. No pairing, encryption or user interaction is required; the code is compiled in when CONFIG_BT_CTLR_PERIPHERAL_ISO or CONFIG_BT_CTLR_CENTRAL_ISO is enabled. In default builds (CONFIG_BT_CTLR_ASSERT_DEBUG is default y) the retained-node assertion fires immediately, producing a controller fatal error and, typically, a system reset from one injected PDU. With the development assertions disabled, each attempt permanently loses one node from the controller's small LL notification pool (LL_PDU_RX_CNT, 2 * CONFIG_BT_CTLR_LLCP_CONN) together with its memq_link_t; repeating the connect-attack-reconnect cycle exhausts the pool, after which notification allocation always fails, RX flow control stalls, and the non-disableable LL_ASSERT_ERR() in llcp_lp_cc_flush() faults. The impact is limited to availability — the leaked node is orphaned, never reused or double-freed — and recovery requires a reboot.
How to fix
No published remediation has been found for this vulnerability's affected products yet.
Mitigation guidance may be in the linked vendor advisories in the References section below.
TridentStack Control tracks known vulnerabilities across your Windows, macOS, and Linux fleet and shows the fix as soon as one is published. See how it works
CVSS v3 Vector
Exploitability
Impact
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Exploit Intelligence
Low risk: more likely to be exploited than 1% of all known CVEs.
References
Related Vulnerabilities
Other CWE-401 (Missing Release of Memory (Memory Leak)) vulnerabilities, ordered by exploit likelihood. View all
| CVE | Severity | CVSS | EPSS | Exploited | Fix |
|---|---|---|---|---|---|
| CVE-2020-13934 | High | 7.5 | 64% | - | Fix |
| CVE-2016-6304 | High | 7.5 | 63% | - | Fix |
| CVE-2019-12265 | Medium | 5.3 | 60% | - | Fix |
| CVE-2001-0136 | Medium | 5.0 | 45% | - | - |
| CVE-2016-4232 | High | 7.5 | 36% | - | - |
| CVE-2001-0543 | Medium | 5.0 | 19% | - | - |
Common questions
How do I fix CVE-2026-19738?
No published fix for CVE-2026-19738 has been found yet. Check the linked vendor advisories for guidance as it becomes available.
Is CVE-2026-19738 being actively exploited?
Not that we know of. CVE-2026-19738 is not in the CISA Known Exploited Vulnerabilities catalog. Its EPSS score of 0.10% is the estimated probability that it will be exploited in the next 30 days. That is higher than 1% of all scored CVEs.
How severe is CVE-2026-19738?
CVE-2026-19738 has a CVSS v3 base score of 6.5, rated medium. CVSS rates the technical impact if the vulnerability is exploited, not how likely that is, so weigh it alongside the exploit-prediction score when you decide what to patch first.
Embed a live status badge for CVE-2026-19738
Markdown
[](https://tridentstack.com/cve/CVE-2026-19738)HTML
<a href="https://tridentstack.com/cve/CVE-2026-19738"><img src="https://tridentstack.com/cve/badge/CVE-2026-19738.svg" alt="CVE-2026-19738"></a>Find and fix vulnerabilities across your fleet
TridentStack Control continuously scans your Windows, macOS, and Linux fleet for known vulnerabilities, prioritizes them by severity and active exploitation, and patches them automatically.
This product uses NVD data but is not endorsed or certified by the NVD. EPSS scores courtesy of FIRST.org (https://www.first.org/epss). Source: CISA KEV Catalog. Data as of 2026-10-16.