CVE-2026-20320
HIGHCISA KEVDescription
A vulnerability in the Open Client Interface (OCI) XML Parser of Cisco BroadWorks could allow an unauthenticated, remote attacker to read sensitive configuration information on an affected system. This vulnerability exists because XML entries are improperly parsed due to external entity resolution being allowed by default. An attacker could exploit this vulnerability by sending a crafted XML message to the Open Client Interface – Provisioning (OCI-P) service. A successful exploit could allow the attacker to view sensitive files from the filesystem with the privileges of the Cisco BroadWorks user.
How to fix
TridentStack Control can deploy fixes like this automatically across your Windows, macOS, and Linux fleet. See how it works
Remediation is compiled from vendor and distribution security advisories. Always confirm against the linked source for your exact version and platform.
CVSS v3 Vector
Exploitability
Impact
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Exploit Intelligence
Moderate risk: more likely to be exploited than 63% of all known CVEs.
Remediation due: 2026-11-24
References
Related Vulnerabilities
Other CWE-611 (XML External Entity (XXE)) vulnerabilities, ordered by exploit likelihood. View all
| CVE | Severity | CVSS | EPSS | Exploited | Fix |
|---|---|---|---|---|---|
| CVE-2024-34102 | Critical | 9.8 | 100% | KEV | Fix |
| CVE-2019-9670 | Critical | 9.8 | 100% | KEV | Fix |
| CVE-2022-28219 | Critical | 9.8 | 97% | - | - |
| CVE-2024-22024 | High | 8.3 | 95% | - | - |
| CVE-2017-12629 | Critical | 9.8 | 92% | - | Fix |
| CVE-2024-38653 | High | 7.5 | 92% | - | - |
Common questions
How do I fix CVE-2026-20320?
Published advisories record a fix for 4 affected products. The "How to fix" section on this page lists the fixed version and source advisory for each one, so apply the entry matching what you actually run.
Is CVE-2026-20320 being actively exploited?
Yes. CVE-2026-20320 is listed in the CISA Known Exploited Vulnerabilities catalog, which means exploitation has been observed in the wild. US federal agencies were required to remediate it by 2026-11-24. Treat it as a priority whatever its CVSS score says.
How severe is CVE-2026-20320?
CVE-2026-20320 has a CVSS v3 base score of 7.5, rated high. CVSS rates the technical impact if the vulnerability is exploited, not how likely that is, so weigh it alongside the exploit-prediction score when you decide what to patch first.
What does CVE-2026-20320 affect?
Published advisories record a fix for broadworks application delivery platform (NVD), broadworks application server (NVD), broadworks profile server (NVD), broadworks xtended services platform (NVD). Only products with a sourced advisory are listed, so treat this as what we can cite rather than a complete inventory.
Embed a live status badge for CVE-2026-20320
Markdown
[](https://tridentstack.com/cve/CVE-2026-20320)HTML
<a href="https://tridentstack.com/cve/CVE-2026-20320"><img src="https://tridentstack.com/cve/badge/CVE-2026-20320.svg" alt="CVE-2026-20320"></a>This vulnerability is actively exploited in the wild
TridentStack Control detects known-exploited CVEs across your Windows, macOS, and Linux fleet and prioritizes their patches. 200 endpoints free forever.
This product uses NVD data but is not endorsed or certified by the NVD. EPSS scores courtesy of FIRST.org (https://www.first.org/epss). Source: CISA KEV Catalog. Data as of 2026-11-16.